Sorry for the wall of text… This ended up a lot longer than I thought it would…

TL:DR - Looking for guide to partitioning/booting and/or help with Clover config.

Background

I recently purchased a used Dell PowerEdge R730xd to use as a home lab/self-hosting project. The intention being I would install Proxmox and play around with it and see what I wanted to add in to it later. As the server did not include any drives, I figured I would purchase a PCIe to NVMe adapter to work as the “boot” drives for the system and then fill up the 24 drive bays over time if I decided I wanted to continue with the setup.

I purchased one of the Asus Hyper M.2 x16 PCIe NVMe cards that supports up to 4 drives. To go along with it, I purchased 2x 1TB Samsung 980 Pros. I had done some research ahead of time knowing this might cause some issues, but it appeared that they could be worked through.

Installation

I installed the drives and card and turned on PCIe bifurcation for the slot. The server/iDRAC didn’t see the devices, but this was expected based on prior research.

Using Dell’s iDRAC, I was able to virtually attach the Proxmox .iso and boot into the installer just fine. For my Proxmox install, I chose to use “zfs (RAID1)” with both 980’s as the drives. Installation appeared to go through without a problem and I rebooted to finalize the install.

At this point, the server does not recognize a boot option and hangs in the POST menu asking what to do.

Problem and Possible Solution

I was aware this might be an issue. From what I’ve gathered, the server won’t boot because of them being NVMe in the PCIe slots. Plus the fact that they don’t even appear in iDRAC or BIOs confirms this.

I had discovered this is a common issue and that people suggest using Clover as a way to “jump start” the boot process.

I found this guide where someone appears to have gone through a very similar process (although for VMware ESXi) that seemed to have enough clues to what I’d need to do.

I installed Clover to a flash drive and did the steps to move in the nvme drivers, booted into Clover, and created the “preboot.log” file. I then started to edit/create the config.plist file as they described in the guide. This is the stage where I ran into problems…

Troubleshooting and Where I Need Help

When I opened the preboot.log file and did the search for “nvme”, I found multiple listings. (Copy of the preboot section below for reference.) This is where my understanding of things starts to run out and I need help.

There are 8x volumes with NVMe being referenced. (The USB listings I assume are from the Clover boot media.) Just looking at the numbers, I think this means there are 4 partitions per physical drive? I assume that the RAID1 install means things are duplicated between the 2 drives.

I did some more research and found this guide on the Proxmox forums. They mention starting into the Proxmox installer and doing a debug install to run fdisk and blkid to get the PARTUUID. The second post mentions a situation that sounded exactly like mine and provided a config file with some additional options.

I got into the debug menu and ran fdisk and blkid (results copied below). This again is where I struggle to understand what I am seeing because of my lack of understanding of file-structures/partitioning/boot records.

The Request(s)

What I was hoping to find out from this post was a few things.

  1. Can someone explain the different pieces of information from the fdisk and blkid commands and preboot.log? I’ve done some work with fixing my other Linux server in the past and remember seeing some of this, but I never fully “learned” what I was seeing. If someone has a link that explains the columns, labels, under-lying concepts, etc, that’d be great! I wasn’t able to find one and I think it’s because I don’t know enough to even form a good query…
  2. Hopefully someone out there has experienced this problem and can look at what I’ve got and tell me what I’ve done wrong. I feel like I am close, but just missing/not understanding something. I fully assume I’ve either used the incorrect volume keys for my config, or something else in the config file. I’m leaning on the former, hence point 1.
  3. If anyone has a “better” way to get Proxmox to boot with my current hardware, I’d like to hear it. My plan was to get Clover working and install that on the vFlash card in the server and just have that jump start the boot on a reboot.
  4. Hopefully this can serve as a guide/help someone else out there.

Let me know if you need more information. I am posting this kind of late so I might not get back to your question(s) until tomorrow.

fdisk

(Please note that I had to manually type this as I only had a screenshot that I couldn’t get to upload. There might be typos.)

fdisk -l
Disk /dev/nvme0n1: 932GB, 1000204886016 bytes, 1953525168 sectors
121126 cylinders, 256 heads, 63 sectors/track
Units: sectors of 1 * 512 = 512 bytes

Device		Boot	StartCHS	EndCHS		StartLBA	    EndLBA	   Sectors	Size	ID	Type
/dev/nvme0n1p1		0,0,2		1023,255,63		1	1953525167	1953525167	931G	ee	EFI GPT
Disk /dev/nvme1n1: 932GB, 1000204886016 bytes, 1953525168 sectors
121126 cylinders, 256 heads, 63 sectors/track
Units: sectors of 1 * 512 = 512 bytes

Device		Boot	StartCHS	EndCHS		StartLBA	    EndLBA	   Sectors	Size	ID	Type
/dev/nvme1n1p1		0,0,2		1023,255,63		1	1953525167	1953525167	931G	ee	EFI GPT

blkid

(Please note that I had to manually type this as I only had a screenshot that I couldn’t get to upload. There might be typos.)

blkid
/dev/loop1: TYPE="squashfs"
/dev/nvme0n1p3: LABEL="rpool" UUID="3906746074802172538" UUID_SUB="7826638652184430782" BLOCK_SIZE="4096" TYPE="zfs_member" PARTUUID="c182c6d2-6abb-40f7-a204-967a2b6029cc"
/dev/nvme0n1p2: UUID="63F3-E64B" BLOCK_SIZE="512" TYPE="vfat" PARTUUID="06fc76a4-ed48-4f0e-84ed-f602f5962051"
/dev/sr0: BLOCK_SIZE="2048" UUID="2023-06-22-14-56-03-00" LABEL="PVE" TYPE="iso96660" PTTYPE="PMBR"
/dev/loop0: TYPE="squashfs"
/dev/nvme1n1p2: UUID="63F6-0CF7" BLOCK_SIZE="512" TYPE="vfat" PARTUUID="8231936a-7b2c-4a96-97d6-b80393a3e7a1"
/dev/nvme1n1p3: LABEL="rpool" UUID="3906746074802172538" UUID_SUB="11940256894351019100" BLOCK_SIZE="4096" TYPE="zfs_member" PARTUUID="f57fc276-bca6-4779-a161-ebe79db3275e"
/dev/nvme0n1p1: PARTUUID="7c249bb3-b7fb-4ebf-a5ae-8d3b9b4b9ab5"
/dev/nvme1n1p1: PARTUUID="0a796a75-41a4-4f57-9c1f-97817bb30963"

preboot.log

117:268  0:000  === [ ScanVolumes ] =============================
117:268  0:000  Found 11 volumes with blockIO
117:268  0:000  - [00]: Volume: PciRoot(0x0)\Pci(0x1A,0x0)\USB(0x0,0x0)\USB(0x4,0x0)\USB(0x0,0x0)
117:273  0:005          Result of bootcode detection: bootable unknown (legacy)
117:273  0:000  - [01]: Volume: PciRoot(0x0)\Pci(0x1A,0x0)\USB(0x0,0x0)\USB(0x4,0x0)\USB(0x0,0x0)\HD(1,MBR,0x3522AA59,0x3F,0x64000)
117:276  0:003          Result of bootcode detection: bootable unknown (legacy)
117:276  0:000            label : BDU
117:276  0:000          This is SelfVolume !!
117:276  0:000  - [02]: Volume: PciRoot(0x0)\Pci(0x1A,0x0)\USB(0x0,0x0)\USB(0x4,0x0)\USB(0x0,0x0)\HD(2,MBR,0x3522AA59,0x6403F,0x70CFC1)
117:280  0:003          Result of bootcode detection: bootable unknown (legacy)
117:280  0:000  - [03]: Volume: PciRoot(0x1)\Pci(0x2,0x0)\Pci(0x0,0x0)\NVMe(0x1,BD-15-A3-31-B6-38-25-00)
117:280  0:000          Result of bootcode detection: bootable Linux (grub,linux)
117:280  0:000  - [04]: Volume: PciRoot(0x1)\Pci(0x2,0x0)\Pci(0x0,0x0)\NVMe(0x1,BD-15-A3-31-B6-38-25-00)\HD(1,GPT,7C249BB3-B7FB-4EBF-A5AE-8D3B9B4B9AB5,0x22,0x7DE)
117:280  0:000          Result of bootcode detection: bootable unknown (legacy)
117:280  0:000  - [05]: Volume: PciRoot(0x1)\Pci(0x2,0x0)\Pci(0x0,0x0)\NVMe(0x1,BD-15-A3-31-B6-38-25-00)\HD(2,GPT,06FC76A4-ED48-4F0E-84ED-F602F5962051,0x800,0x200000)
117:281  0:000          Result of bootcode detection: bootable unknown (legacy)
117:283  0:002            label : EFI
117:283  0:000  - [06]: Volume: PciRoot(0x1)\Pci(0x2,0x0)\Pci(0x0,0x0)\NVMe(0x1,BD-15-A3-31-B6-38-25-00)\HD(3,GPT,C182C6D2-6ABB-40F7-A204-967A2B6029CC,0x200800,0x7450658F)
117:283  0:000  - [07]: Volume: PciRoot(0x1)\Pci(0x2,0x1)\Pci(0x0,0x0)\NVMe(0x1,F1-1B-A3-31-B6-38-25-00)
117:283  0:000          Result of bootcode detection: bootable Linux (grub,linux)
117:283  0:000  - [08]: Volume: PciRoot(0x1)\Pci(0x2,0x1)\Pci(0x0,0x0)\NVMe(0x1,F1-1B-A3-31-B6-38-25-00)\HD(1,GPT,0A796A75-41A4-4F57-9C1F-97817BB30963,0x22,0x7DE)
117:283  0:000          Result of bootcode detection: bootable unknown (legacy)
117:283  0:000  - [09]: Volume: PciRoot(0x1)\Pci(0x2,0x1)\Pci(0x0,0x0)\NVMe(0x1,F1-1B-A3-31-B6-38-25-00)\HD(2,GPT,8231936A-7B2C-4A96-97D6-B80393A3E7A1,0x800,0x200000)
117:283  0:000          Result of bootcode detection: bootable unknown (legacy)
117:286  0:002            label : EFI
117:286  0:000  - [10]: Volume: PciRoot(0x1)\Pci(0x2,0x1)\Pci(0x0,0x0)\NVMe(0x1,F1-1B-A3-31-B6-38-25-00)\HD(3,GPT,F57FC276-BCA6-4779-A161-EBE79DB3275E,0x200800,0x7450658F)

config.plist





  Boot
  
    Timeout
    5
    DefaultVolume
    LastBootedVolume
  
  GUI
  
    Custom
    
      Entries
      
        
          Path
          \EFI\systemd\systemd-bootx64.efi
          Title
          ProxMox
          Type
          Linux
          Volume
          06FC76A4-ED48-4F0E-84ED-F602F5962051
          VolumeType
          Internal
        
        
          Path
          \EFI\systemd\systemd-bootx64.efi
          Title
          ProxMox
          Type
          Linux
          Volume
          8231936A-7B2C-4A96-97D6-B80393A3E7A1
          VolumeType
          Internal
        
      
    
  




  • BlueÆther
    link
    fedilink
    English
    31 year ago

    I had the same issue on an IBM m4 (with out bifurcation), I have tried with Clover and had limited success. What I’m doing at the moment is I have proxmox installed to a single nvme and the same iso installed to a thumb drive.

    I then, on first boot, remapped the boot pool to point to the nvme drive. Down side is I have to update the kernel on both the thumdrive and nvme drive if I need to update the kernel version

    • Ac5000OP
      link
      fedilink
      English
      11 year ago

      What were the issues you had with Clover in particular? I’d be interested to hear since I’m trying to head down that path myself.

      For your “remap” can you explain what you did/have an example? I think this might give me the knowledge I’m lacking since I think part of my problem is not understanding which partition/PARTUUID is the Proxmox boot/what I should point Clover at.

      • BlueÆther
        link
        fedilink
        English
        2
        edit-2
        1 year ago

        I cant remember what the issue was sorry

        If you go down the route of booting off a usb key to chain load proxmox there will be no real ware to the usb as it’s only used for booting.

        On thye first boot it proxmox will complain that there are two zvol with the same name, and you just rename the one on the USB to ***_USB or the like and then continue the boot - I think I did a post on reddit or proxmox forum on how to do this

        Edit, found it https://www.reddit.com/r/Proxmox/comments/ybxcxx/using_clover_to_boot_of_my_nvme_drive/

        I have a M4 that I did this for:

        Install proxmox to NVME as ZFS

        Install proxmox to USB as ZFS

        On first boot change the USB ZFS rootfs to a new name (this is from the top of my head but is backed up by thegeekdiary.com):

        zpool import // find the ID of the NVME pool
        
        zpool import -f NNNNNNNNNNNN
        
        zpool import rootfs rootfsusb
        
        zpool export rootfsusb
        
        reboot
        
        • Ac5000OP
          link
          fedilink
          English
          11 year ago

          Thank you for responding and providing the link and info. The top comment in that reddit post has the same link I posted above.

          For the

          zpool import // find the ID of the NVME pool

          How did you find the ID of the NVME pool? I think is part of the problem I have where I see multiple partitions and not entirely sure which is the “boot” partition I should be pointing to. I think in your case, you’re pointing to the “data” partition, but this might help me eliminate one of my options.

          I’m also not sure how the raid1 plays into things since it seems like both physical drives seem to have the same partitions. Not sure if I can just point to one of the “boot” partitions on one of the drives and it’ll find it’s partner when it starts booting?

          • BlueÆther
            link
            fedilink
            English
            21 year ago

            the command zpool import will list all the pools and IDs